FANDOM


After the IBM TRIRIGA Application Platform installation is complete, verify that your installation is running properly. This verification checklist is not intended to replace your company testing and validation procedures.

Item Description
Inspecting the installation log

Read the ant.log file. This file contains information about that steps that were taken during the installation. The file is written to the IBM TRIRIGA root installation directory. For example, on Windows, C:\Tririga\ant.log is the typical location. A line toward the end of the file indicates whether the installation succeeded or failed, such as the following examples:

  • The installation succeeded:
BUILD SUCCESSFUL
Total time: 25 minutes 51 seconds
  • The installation failed:
BUILD FAILED
C:\Tririga\build.xml:2586: The following error
occurred while executing this line:
C:\Tririga\build.xml:2141: Java returned: -1
Total time: 8 minutes 44 seconds
Starting the application Start IBM TRIRIGA by locating the application server directory with the appropriate method.
Accessing the application Verify your access to the IBM TRIRIGA application as the system user as follows:
  • Specify the URL address in your browser address field. The URL looks something like http://[hostname:port][/context_path], where [hostname:port] and [/context_path] are the specific values for your environment. If you see the error message "Unable to launch the application", then you must set the FRONT_END_SERVER property.
  • Sign in with your user name and password. The default user name is "system" and the default password is "admin".
Accessing the administrator console Verify your access to the IBM TRIRIGA administrator console as follows.
  • Specify the URL address in your browser address field. The URL looks something like http://[hostname:port][/context_path]/html/en/default/admin, where [hostname:port] and [/context_path] are the specific values for your environment.
  • Sign in with your user name and password. The default user name is "system" and the default password is "admin".
  • In the Agent Manager, start the following agents in the process server: Cleanup Agent, Extended Formula Agent, Formula Recalc Agent, Scheduler Agent, Workflow (WF) Agent, and Workflow (WF) Notification Agent.
  • Sign out of the administrator console.
Creating users and records As the system user, create and verify an IBM TRIRIGA employee who is not an administrator as follows:
  • Assign the user to several user groups, but not all of them.
  • Assign the user with several user licenses, but not all of them.
  • Sign in as the user that you created.
  • Verify that the user can access everything that the employee is meant to access, according to the assigned groups and licenses.
  • Verify that the user can create and revise records, such as people records and location records.
  • Verify that the association tree loads in the Associations tab of an opened record.
Using the builder tools As the system user, open and verify the builder tools under Tools > Builder Tools as follows:
  • In the workflow builder, verify that workflows load completely by opening and revising existing workflows.
  • In the data modeler, verify that the state transitions load completely.
  • In the data modeler, verify that the simple mail transfer protocol (SMTP) email notification works by publishing a test business object.
Using the Document Manager As either the system user or a user with rights, open and verify the Document Manager under Tools > Document Manager as follows:
  • Verify that the user can upload new documents, such as .txt, .html, and .jpg files.
  • Verify that the user can upload new documents with the multifile applet.
  • Verify that the user can view documents by clicking the icon in the V column.
  • Verify that the user can check in and check out documents.
  • If Brava is installed, verify that the user can upload computer-aided design (CAD) documents in .dxf format and view the CAD documents by clicking the icon in the V column.
Editing project tasks As either the system user or a user with rights, verify the functions that are dependent on the X Window System as follows:
  • Create or open a new capital project.
  • In the Schedule tab, add or open a task in the Project Tasks section.
  • In the task, edit the planned start date, planned end date, or planned working hours.
  • Verify that when one field is edited, the other two fields are adjusted automatically.
Syncing CAD drawings If IBM TRIRIGA CAD Integrator/Publisher is being used, verify your access to IBM TRIRIGA as follows:
  • Start TRIRIGA CAD Integrator/Publisher.
  • Sign in as a user with a TRIRIGA CAD Integrator/Publisher license.
  • Verify that the user can sync a CAD drawing with TRIRIGA CAD Integrator/Publisher.
Inspecting the server log Verify that the server.log file exists for each application server and process server. This file is written to the log directory of the IBM TRIRIGA installation. For example, on Windows, C:\Tririga\log\server.log is the typical location. In addition:
  • Verify that the application server is writing to its server.log file. Inspect the file for any major exceptions on first startup.
  • Verify that the process server is writing to its server.log file. One day after the installation and on a regular basis, verify that the process server completed the cleanup process successfully.
Inspecting the properties file If you installed the IBM TRIRIGA Application Platform in a performance or production environment, open the TRIRIGAWEB.properties file to verify that the ProductionMode property is set to the value of Y (yes) instead of the default value of N (no). This file is in the config directory of the IBM TRIRIGA installation. For example, on Windows, C:\Tririga\config is the typical location.